INSTALLATION & OPERATION MANUAL
MODEL NUMBERS: 25-PDVC 55-SHP10 55-TRP10
Thank you for purchasing this product from a fine line of heating equipment. We wish you many
years of safe heating pleasure with your new heating appliance.
Save These Instructions.
IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE
DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
Please Note the Following Precautionary Statements:
NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT.
CAUTION: Please read this entire manual before installation and use of this pellet
fuel burning room heater.
Keep children, furniture, fixtures, and all combustible materials away from
any heating appliance. Refer to this owner’s manual for all clearances to
combustible materials.
WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT.
DO NOT OPERATE UNIT WITH HOPPER OPEN. LID MUST BE SHUT AND TIGHTLY SECURED.
DO NOT OPERATE WITH DOOR OPEN
SAFETY NOTICE
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL
THE INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS
FOR RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS (INCLUDING
PERMITS) IN YOUR AREA.
Questions? Need Parts or Options? www.englanderstoves.com
Rev. 2/10
England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide
detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when
using smoke or Carbon Monoxide detectors.
Mobile Home Use:
These freestanding pellet units are approved for mobile home or doublewide installation with
outside combustion air hook-up. See “Flue System” section of manual.
Mobile home installation should be in accordance with the Manufactured Home and Safety
Standard (HUD), CFR 3280, Part 24.
WARNING
: Do Not Install in Sleeping Room
CAUTION
: The structural integrity of the mobile home floor, wall and ceiling/roof
m
ust
be
m
a
in
ta
in
ed
.
Seitenansicht 0
1 2 3 4 5 6 ... 26 27

Inhaltsverzeichnis

Seite 1 - SAFETY NOTICE

INSTALLATION & OPERATION MANUAL MODEL NUMBERS: 25-PDVC 55-SHP10 55-TRP10 Thank you for purchasing this product from a fine line of heating equ

Seite 2

10E-Codes “E-Codes,” or Error Codes, are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experien

Seite 3 - IN THE EVENT OF SMOKE-BACK

11DAILY OPERATION Refueling the Unit Always press the “OFF” touch pad before refueling. This unit has a 40-lb. hopper, and should be refilled when t

Seite 4 - IMPORTANT INFORMATION

12 ASH REMOVAL AND DISPOSAL IMPORTANT: While the amount of ash generated by this unit is not excessive compared to log-burning woodstoves, keepi

Seite 5 - UNIT PREPARATION

13Monthly Ash Removal The large baffle plate (12” x 13”) that hangs above and behind the burn pot (refer to the exploded diagram in the rear of

Seite 6

14MAINTENANCE CAUTION: UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK! SEE EXPLODED DIAGRAM (ILLUSTRATION 6) FOR PARTS REFERENCE Parts Orders: (800) 5

Seite 7 - Our Outside

15Vacuum Switch This unit is equipped with Vacuum Shut Down Switches (Part # PU-VS and CU-VS), which help control various functions of the unit. If

Seite 8

16 Hopper Lid Safety Switch This unit is also equipped with a hopper lid safety switch (Part # PU-HLS) which is directly connected to the top auger

Seite 9 - OPERATING INSTRUCTIONS

17Control Board The Control Board (Part # PU-CB04) is a digital read-out board. This board offers a wide variety of settings to operate the unit. T

Seite 10

18 CAUTION: Moving Parts May Cause Injury. Do NOT Operate with Panel(s) Off. DANGER: Parts May Be Hot. Risk of E

Seite 11 - DAILY OPERATION

19Adjusting Hopper Lid Latches The seals around the top of the pellet hopper are important to safe an efficient operation of the unit. The latches i

Seite 12 - ASH REMOVAL AND DISPOSAL

2A letter from our Technical Support Department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works

Seite 13

20ACCESSORY ITEMS The following accessories can be added to your unit at anytime after purchase; however, let the unit cool down before adding any a

Seite 14 - MAINTENANCE

21REPLACEMENT PARTS, ACCESSORIES AND OPTIONS AC-GGK Glass Gasket Kit (gasket only, no glass) AC-DGKC Door Gasket Kit (#2 on diagram) AC-G9 9” x

Seite 15

22 Pellet Stove – Exploded View DiagramIllustration 6 Unit Dimensions: 23" W x 28" H x

Seite 16

23TROUBLE-SHOOTING GUIDE WARNING: TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE ATTEMPTING ANY REPAIR. IF THIS G

Seite 17 - Caution

24 You may write your unit’s Manufacture Date and Serial Number in the blank spaces on this sample

Seite 18

25Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number ________________

Seite 20 - ACCESSORY ITEMS

27WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address ___________________

Seite 21 - (includes 3” adapter)

3BEFORE RE-STARTING YOUR UNIT Every time before pressing “ON” to start your unit – Be sure to remove all ashes (burnt or partially burnt) from your

Seite 22 - Illustration 6

4IMPORTANT INFORMATION 1. Check local installation codes for your area. Call your Homeowner’s Insurance representative for inspection of your stov

Seite 23 - TROUBLE-SHOOTING GUIDE

5 14. Do not allow paint, chemicals or construction dust on or near your unit. Do not allow liquid or ANY foreign materials on or inside your unit.

Seite 24

6 FLUE SYSTEM Caution: Follow the pipe manufacturer’s installation instructions and directions for passing through combustible walls and cei

Seite 25 - LIMITED 5 YEAR WARRANTY

7 The through-the-wall installation is the least expensive and simplest installation. In a through-the-wall installation you should be mindful

Seite 26

8 FLOOR AND WALL PROTECTION Floor Protection If your floor is constructed of a non-combustible material such as bri

Seite 27

9OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE WITH THE DOOR OPEN. If door is left open (approximately) two minutes, unit will stop feeding and fi